Blocking off a fireplace is a practical way to stop drafts, keep out animals, or simply hide an unused hearth. This guide covers temporary and semi-permanent methods, from a simple chimney balloon to a more solid plywood cover. Before starting, measure the opening and decide whether you need to keep the flue functional or seal it completely. Always ensure the fire is fully out and the fireplace is cold before beginning.
What You’ll Need
- Tape measure
- Chimney balloon (or rigid foam insulation board as an alternative)
- Plywood (if building a solid cover)
- Screws and a drill (for a solid cover)
- Caulk or weatherstripping
- Utility knife
- Safety glasses and dust mask
Step-by-Step
- Measure the opening. Use a tape measure to get the width and height of the fireplace opening at its widest points. Write these numbers down—you’ll need them for the balloon or cover.
- Clean the fireplace. Remove any ash, soot, or debris. Vacuum the floor and walls of the firebox. This prevents dust and odors from escaping when you seal it.
- Choose your method. For a temporary block (e.g., for a season), a chimney balloon or a piece of rigid foam cut to size works well. For a more permanent cover, use plywood screwed into the masonry.
- Install a chimney balloon (temporary). Inflate the balloon according to the manufacturer’s instructions, then insert it into the flue (the opening above the firebox). Position it so it expands to seal the flue tightly. Pull the inflation tube through the damper area so you can deflate it later. This method stops drafts effectively but is not a permanent seal.
- Alternative: Cut foam board (temporary). If you prefer a rigid barrier, cut a piece of rigid foam insulation to fit snugly inside the firebox opening. Use a utility knife and score a line, then snap the board. Press it in place, and seal the edges with weatherstripping tape. This is easy to remove but less airtight than a balloon.
- Build a plywood cover (semi-permanent). Cut a piece of plywood to the exact dimensions of the opening. Drill pilot holes through the plywood into the masonry (use masonry bits for brick or stone). Insert masonry anchors, then screw the plywood into place. Caulk around the edges to seal gaps. This creates a solid barrier that can be painted to match your wall.
- Seal gaps. For any method, use caulk or weatherstripping to fill small gaps around the edges. This ensures a tight seal against drafts and pests.
- Label the flue (if using a balloon). Attach a tag or note to the inflation tube that says “Flue blocked” so no one accidentally lights a fire.
Common Mistakes
- Forgetting to check for a working damper. If your damper is broken, a balloon may not seal properly. Test the damper before installing.
- Using a balloon in a fireplace with a weak flue. Chimney balloons are meant for masonry flues; they may not work in metal flues or prefabricated fireplaces. Check compatibility.
- Not measuring correctly. A cover that is too small leaves gaps; one that is too large won’t fit. Measure twice, cut once.
- Ignoring ventilation. If you block the fireplace completely, the room may need alternative ventilation, especially if you have a gas appliance or furnace that relies on combustion air. Consult a professional if unsure.
- Skipping the label. Without a clear warning, someone might light a fire and cause a dangerous backup.
Tips
- For a temporary block, consider a chimney balloon with a built-in release valve—it’s easy to remove when you want to use the fireplace again.
- If you choose plywood, use exterior-grade plywood to resist moisture and warping.
- Add a layer of rigid foam insulation behind the plywood for better thermal performance.
- If you have a gas line or other utility in the fireplace, have a professional disconnect it before sealing.
- For a decorative touch, paint the plywood cover or cover it with fabric to blend with your room.
Troubleshooting
The balloon won’t stay inflated. Check for leaks by listening for hissing. If the balloon has a slow leak, it may be defective—replace it. Ensure the inflation tube is sealed properly.
Drafts still come through. Re-check the edges. Use more caulk or weatherstripping. If the flue is wide, the balloon may not expand enough—use a larger size or add a second balloon.
The plywood cover doesn’t fit flush. The opening may not be perfectly rectangular. Use a compass or cardboard template to trace the exact shape, then transfer it to the plywood. Sand the edges slightly for a better fit.
You notice a musty smell. This could be moisture building up. Ensure the fireplace is completely dry before sealing. If the smell persists, check for water leaks in the chimney—call a professional if you suspect damage.
You need to use the fireplace again. If you used a balloon, deflate it and remove it. If you used plywood, unscrew it and patch the holes with masonry filler. Always have the flue inspected before lighting a fire.
Frequently Asked Questions
Can I block off a fireplace permanently? Yes, but a permanent block typically involves building a wall or installing a damper. This is a major renovation—consult a contractor to ensure proper ventilation and safety.
Will blocking a fireplace cause mold? Possibly, if moisture gets trapped. Ensure the fireplace is dry and the area is well-ventilated. A chimney balloon can allow some airflow if not fully inflated, but a solid cover may trap moisture. Consider adding a dehumidifier in the room.
How do I know if my flue is safe to block? Have a chimney sweep inspect it first. They can check for cracks, creosote buildup, and proper clearance. Blocking a damaged flue can be dangerous.
Can I use a fireplace cover to block a gas fireplace? No, gas fireplaces have specific venting requirements. Never block a gas fireplace without professional guidance, as it can cause carbon monoxide buildup.
What’s the best way to block a fireplace for winter? A chimney balloon is the most effective for stopping drafts, but it must be removed before any fire. For a more permanent winter block, use plywood with insulation.
Is it safe to block a fireplace if I have a wood stove? No, wood stoves require proper clearances and venting. Blocking the flue of a wood stove can cause dangerous smoke and gas buildup. Always follow manufacturer guidelines.